無料 · ネットワーク・IT インフラ
ストレージ IOPS 計算機.
IOPS、読み書き比率、RAID の書き込みペナルティから必要なドライブ数を求め、HDD・SATA SSD・NVMe を比較します。
CALCULATED IN YOUR BROWSER · NOTHING IS UPLOADED
Use sustained mixed-workload figures, not the peak 4K read number from a datasheet.
Drives needed186RAID 1 / RAID 10 · IOPS-bound
- Back-end IOPS (after write penalty)
- 26,000
- Drives for IOPS
- 186
- Drives for capacity
- 17
- Throughput at this I/O size
- 163.8 MB/s
- Usable capacity of the array
- 223.2 TB
- Functional IOPS of the array
- 20,031
Same workload on other drives
| Drive type | Drives for IOPS |
|---|---|
| 7,200 rpm HDD | 325 |
| 10,000 rpm SAS HDD | 186 |
| 15,000 rpm SAS HDD | 137 |
| SATA SSD (sustained mixed) | 2 |
| NVMe SSD, data-centre (sustained mixed) | 2 |
- Functional IOPS = raw IOPS × read % + raw IOPS × write % ÷ write penalty. Controller caches and SSD tiers can hide part of the penalty.
- Replace the per-drive IOPS with figures measured with fio or the vendor’s steady-state numbers for your block size.
使い方: ストレージ IOPS 計算機
データを入力するかファイルを選び、設定を調整して結果を生成します。コピーやダウンロードの前に結果を確認してください。
制限と対応形式
入力内容はお使いの端末で処理されます。
英語の技術説明
Per-drive IOPS are conservative sustained values; use measured or vendor steady-state figures. Controller and SSD caches are not modelled. Everything is calculated in your browser; nothing is sent or probed on the network.
Back-end IOPS = workload × (read % + write % × write penalty). Drives = back-end IOPS ÷ IOPS per drive, then at least enough for the capacity.
20,000 IOPS at 70 % reads on RAID 10 with 10k SAS drives needs 186 drives; NVMe needs 2.