免费 · 网络与 IT 基础设施
RAID 计算器.
计算 RAID 0、1、5、6、10、50、60 和 ZFS RAIDZ 的可用容量、利用率、容错能力、IOPS、吞吐量和重建时间。
CALCULATED IN YOUR BROWSER · NOTHING IS UPLOADED
Hard drives under production load often rebuild at 50–150 MB/s.
Usable capacity96 TB87.31 TiB as shown by most systems
- Raw capacity (including spares)
- 128 TB
- Storage efficiency
- 75 %
- Drive failures survived
- 2
- Mixed random IOPS
- 900 70 % reads, write penalty 6
- Random read IOPS
- 1,200
- Random write IOPS
- 200
- Sequential read
- 1,500 MB/s
- Sequential write
- 1,500 MB/s
- Rebuild of one drive
- 44.4 h
Other levels with 8 drives of 16 TB
| Level | Usable | Efficiency | Drive failures survived | Mixed IOPS |
|---|---|---|---|---|
| RAID 0 (stripe) | 128 TB | 100 % | 0 | 1,200 |
| RAID 1 (mirror, all drives) | 16 TB | 13 % | 7 | 885 |
| RAID 10 (striped mirrors) | 64 TB | 50 % | 1–4 | 1,020 |
| RAID 5 (single parity) | 112 TB | 88 % | 1 | 930 |
| RAID 6 (double parity) | 96 TB | 75 % | 2 | 900 |
| RAID 50 | 96 TB | 75 % | 1–2 | 930 |
| RAID 60 | 64 TB | 50 % | 2–4 | 900 |
| ZFS RAIDZ1 (one vdev) | 112 TB | 88 % | 1 | 150 |
| ZFS RAIDZ2 (one vdev) | 96 TB | 75 % | 2 | 150 |
| ZFS RAIDZ3 (one vdev) | 80 TB | 63 % | 3 | 150 |
| JBOD / span (no redundancy) | 128 TB | 100 % | 0 | 150 |
- RAID protects against drive failure, not deletion, ransomware, fire or controller faults. Keep separate backups.
- Drive makers use decimal terabytes (10¹² bytes); operating systems often show binary TiB.
使用RAID 计算器的步骤
输入数据或选择文件,调整设置并生成结果。复制或下载之前,请检查结果。
限制与支持格式
输入内容在您的设备上处理。
英语技术说明
Assumes identical drives. ZFS padding and slop space, controller caches and filesystem overhead are not included. RAID is not a backup. Everything is calculated in your browser; nothing is sent or probed on the network.
Usable capacity = data drives × size. Mixed IOPS = raw IOPS × read % + raw IOPS × write % ÷ write penalty. A RAIDZ vdev delivers about one drive’s random IOPS. Rebuild time = drive size ÷ rebuild speed.
8 × 16 TB drives in RAID 6 give 96 TB (87.3 TiB) usable, survive 2 drive failures and rebuild one drive in about 44 hours at 100 MB/s.