Kostenlos · Netzwerk & IT-Infrastruktur
PoE-Budget-Rechner.
Prüfen Sie das PoE-Budget eines Switches für Kameras, Access Points und Telefone nach IEEE-Klasse, Port-Standard (802.3af/at/bt) und tatsächlicher Leistung.
Some devices are not compatible with the port standard or exceed their class.
- Remaining budget
- 13.6 W
- Power at the devices
- 204 W
- Ports used
- 23 / 24
- Heat from devices and cable loss
- 1,216 BTU/h
Devices
| Device | Qty | Class | Reserved at switch | Notes |
|---|---|---|---|---|
| Wi-Fi 6 access point | 4 | 4 | 120 W | OK |
| IP phone | 12 | 2 | 84 W | OK |
| Fixed IP camera | 6 | 3 | 92.4 W | OK |
| PTZ camera | 1 | 6 | 60 W | needs class 6; 802.3at ports give up to class 4 |
- Class reservations are the IEEE power at the switch port (15.4, 30, 60 or 90 W…), which includes the worst-case loss in 100 m of cable.
- Many switches also limit power per port group or need a second power supply for the full PoE budget; check the switch datasheet.
So verwenden Sie das Tool: PoE-Budget-Rechner
Geben Sie Daten ein oder wählen Sie eine Datei. Passen Sie die Einstellungen an, erstellen Sie das Ergebnis und prüfen Sie es vor dem Kopieren oder Herunterladen.
Grenzen und unterstützte Formate
Ihre Eingaben werden auf Ihrem Gerät verarbeitet.
Technische Hinweise auf Englisch
Device profiles are typical values; use the datasheet class. Per-port-group limits and redundant power supplies are not modelled. Everything is calculated in your browser; nothing is sent or probed on the network.
Class allocation reserves the IEEE power at the switch port for each class (15.4, 30, 60, 90 W…). Actual-draw mode scales the device draw by the class’s worst-case cable loss.
4 Wi-Fi 6 APs, 12 phones, 6 cameras and a PTZ reserve 356 W of a 370 W budget; the class 6 PTZ is flagged on 802.3at ports.